CHLO-206A Digital Chlorophyll Sensor

The Apure CHLO-206A is an in-water fluorescence sensor for monitoring chlorophyll-related changes. Interpret its chlorophyll-a estimate with the supplied calibration and site reference samples, and plan routine optical cleaning and verification.

  • Measurement Precision
  • RS485
  • Automation

The CHLO-206A excites algal pigments and measures the emitted fluorescence. A configured relationship reports a chlorophyll-a estimate; the fluorescence signal is not itself a direct count of algal cells or a laboratory extraction result.

The listed optical compensation and ambient-light suppression functions concern instrument response. Confirm the supplied implementation; these functions do not remove every effect of species composition, particle interference, temperature or light-induced fluorescence quenching.

Calibrate and interpret the fluorescence result

  • Use the reference medium, zero/span procedure and acceptance criteria supplied for the CHLO-206A. A dye check can assess response or drift, but it does not alone establish the relationship to every natural algal community.
  • Collect representative water samples at the sensor location for an appropriate laboratory chlorophyll-a analysis. Use paired results to check the concentration relationship across the intended conditions.
  • Record time, depth, light conditions and temperature. Strong-light physiological quenching or a change in species can alter fluorescence without a matching change in pigment concentration.
  • Inspect and clean the optical surface as directed. Verify after cleaning or service and set a site maintenance schedule; online operation does not mean maintenance-free operation.

The listed 0–400 µg/L range and other values remain configuration references. Confirm the concentration basis and accuracy conditions for the ordered sensor. The IP68/depth description requires the supplied installation and connector conditions; a temperature sensor is not universal compensation for all optical effects.

Technical parameter

  • 0-400ug/L
  • Resolution: 0.1ug/L
  • 0-50 °C; IP68 protection, water depth within 20 meters
  • Built-in temperature sensor
  • Support RS-485, Modbus/RTU protocol
  • Convenient, fast, stable and easy to maintain
Chlorophyll sensor detail
BrandApure
ModelCHLO-206A
Measuring range0~400ug/L
Resolution0.1 ug/L,0.1℃
Accuracy±3%,±0.5℃
Digital outputIsolated protection RS485 signal output
Cable length5 meters, other lengths can be customized
Temperature0~50℃