e-201 Lab Glass pH Electrode

The Apure E-201 is a laboratory combination glass pH electrode for use with a compatible pH meter. Confirm sample compatibility, connector and the supplied electrode version before selection.

  • Easy to operate
  • Glass electrode
  • Laboratory use

The E-201 is a laboratory combination glass pH electrode: the measuring glass membrane and reference system are integrated in one probe. Connect it to a compatible high-impedance pH meter. The electrode is not a panel controller and does not itself provide a controller’s 4–20 mA output.

Connection and sample compatibility

The listed laboratory version uses a Q9 connector and an 800 mm shielded cable. Check the actual connector and supplied cable before ordering. The published construction includes a PC body, glass and silicone rubber; confirm chemical and temperature compatibility for the sample and cleaning process.

Use and care

  • Inspect the glass, reference junction and cable. Condition the sensing end as directed by the electrode instructions, and keep the connector clean and dry.
  • Use fresh buffers from the family configured in the meter. Allow temperature and readings to stabilize, and check calibration slope and offset against the meter/electrode requirements.
  • Immerse the measuring glass and reference junction to the specified depth. Avoid bubbles and contact that can damage the glass. Follow the supplied instructions for any refill opening and filling solution.
  • Rinse between solutions and use only an approved cleaning and storage solution. Keep the sensing end hydrated as directed; a rinse with deionized water does not make it a long-term storage solution.

See the pH meter calibration guide for a general workflow. Use the supplied electrode documentation for filling electrolyte, storage, immersion depth and operating limits.

Meter and sample selection

Check the supplied connector, shielding and meter input requirements before replacing an electrode. The connector name alone does not establish electrical or mechanical compatibility. Use the operating range and reference-system instructions for the actual E-201 version when choosing sample temperature, immersion, cleaning and storage conditions.

This laboratory electrode must be used in a suitable laboratory arrangement. A pressure value in a reference illustration does not by itself establish that a complete process connection is suitable for pressurised inline use. Obtain the matching mechanical and operating documentation for any such installation.

BrandApure
ModelE-201
MeasurementpH of compatible aqueous samples
DesignLaboratory combination glass pH electrode
Listed connectionQ9 connector; 800 mm shielded cable in the listed laboratory version
Listed body materialsPC body with glass and silicone rubber components
Before orderingConfirm the supplied connector/cable, operating temperature, pH range, physical dimensions, reference filling solution and compatible meter in the current E-201 documentation.