RP-3000 Automatic pH ORP Controller
The Apure RP-3000 is an online pH/ORP controller for a compatible electrode and temperature input. It provides monitoring and configured control/output functions for the selected measurement arrangement. Match the probe and the supplied input/output version to the process.
- Data remote transmission
- On-line monitoring
- Automation
The Apure RP-3000 is an online pH/ORP controller for a compatible electrode and temperature input. It provides monitoring and configured control/output functions for the selected measurement arrangement. Match the probe and the supplied input/output version to the process.
| Brand | Apure |
|---|---|
| Model | RP-3000 |
| Measuring range | PH: 0~14.00pH ORP: -1999 ~ 1999 mV |
| Resolution | PH: 0.01PH ORP:1mV |
| Accuracy | PH: 1%FS ORP:1%FS |
| Temp | 0~135℃ |
| Signal isolation output | Two 4-20mA outputs for pH and ORP |
| Control interface | Two limited ON/OFF contact output(Relay) |
| Dimensions | 144×144×120mm |
| Cut off dimensions | 138×138mm |
CHARACTERISTICS
- Design of board card modularity, for convenience of assembly and configuration.
- 4.3 inch High-definition screen.
- Isolating transmitting output, with little interference.
- Isolating RS485 communication.
- Can be PH / ORP measurement, temperature measurement, upper and lower limit control, transmission output, RS485 communication.
- Configurable manual and auto temperature offset function.
- Configurable upper/lower limit warning and delay.
- Addition of universal password.
- Industrial controlled door keep, to avoid instrument halted.
Measurement and configuration
pH and ORP use different measurement electrodes and units. Select the input mode and probe specified for the supplied RP-3000 version. Check the actual input-channel arrangement and assign each analogue output in the instrument configuration before system integration.
The temperature range listed for the controller is separate from the operating limits of the selected electrode, reference system and mounting. Verify wetted-material compatibility, process temperature and pressure, installation and access for cleaning before selection.
Installation and calibration
Use the outline and terminal drawings for the supplied instrument; controller case dimensions and the panel opening are different measurements. Confirm the definition of full scale in the accuracy specification, current-output scaling, relay contact ratings and any RS485 communication settings. Calibrate or verify the complete measurement chain according to the supplied controller and electrode instructions.
The pH / ORP technical hub explains why pH and ORP require different electrodes, units, calibration/verification and interpretation. Use it to define the measurement and control requirements before confirming the supplied RP-3000 channel, output and probe configuration.
| Brand | Apure |
|---|---|
| Model | RP-3000 |
| Measuring range | PH: 0~14.00pH ORP: -1999 ~ 1999 mV |
| Resolution | PH: 0.01PH ORP:1mV |
| Accuracy | PH: 1%FS ORP:1%FS |
| Temp | 0~135℃ |
| Signal isolation output | Two 4-20mA outputs for pH and ORP |
| Control interface | Two limited ON/OFF contact output(Relay) |
| Dimensions | 144×144×120mm |
| Cut off dimensions | 138×138mm |