NO2-201 Digital Nitrite Ion Sensor
The Apure NO2-201 is listed as a PVC-membrane nitrite ion-selective sensor for online water monitoring. Specify nitrite-ion (NO2−) or nitrite-as-nitrogen (NO2-N) reporting and verify the supplied electrode configuration.
- Measurement Precision
- High stability
- Long life
NO2-201 is intended for nitrite monitoring, which is distinct from nitrate monitoring with NO3-201. The listed ion-selective design uses a membrane-potential response and calibration to report the target ion; the actual selectivity, operating matrix and output basis must match the supplied probe.
Commission the nitrite channel
- Record whether the calibration standard and output are expressed as NO2− or NO2-N. Match that basis when comparing laboratory results or configuring alarms.
- Condition and calibrate using the nitrite standards and procedure specified for the actual electrode. Use an independent reference sample to verify the result rather than relying only on the calibration points.
- Obtain the model-specific information on interfering ions, pH, ionic strength and suitable sample matrices. Do not transfer nitrate-electrode selectivity or calibration assumptions to this nitrite electrode.
- Verify temperature compensation, drift and membrane condition during routine checks. Temperature correction does not remove chemical interferences.
Installation and communication
- Check the listed 3/4-inch NPT thread, materials, cable, process limits and intended immersion or flow installation for the ordered version.
- Install where the sample is representative and the membrane can be cleaned and serviced. Use the supplied cleaning, conditioning and replacement instructions.
- The listed digital interface supports RS485 Modbus RTU. Confirm power, wiring, register meaning, units and serial settings with the receiving controller or logger.
The original Resolution entry, ±5%F.S., does not define a concentration display increment. It is retained below as an unverified entry. Confirm actual resolution, whether the listed 0~1000mg/L range is as NO2− or as N, and the accuracy and operating conditions for the supplied electrode.
| Brand | Apure |
|---|---|
| Model | NO2-201 |
| Measuring range | 0~1000mg/L |
| Resolution entry — unverified | ±5%F.S. |
| Accuracy | ±5%F.S. |
| Digital output | Isolated protection RS485 signal output |
| Cable length | 5 meters, other lengths can be customized |
| Temperature | 0~40℃ |