APT Air Vortex Flow Transmitter

Apure APT Air Vortex Flow Transmitter is a stress vortex street flow sensor based on karman vortex street principle. Widely applied to measure liquid, gas and steam (including compressed gas) the cumulative flow and transient flow, oil, chemical, metallurgical, and urban water supply, gas pipeline industry such as volume measurement of the ideal instrument.

  • High accuracy, wide measuring range
  • Can measure liquid, gas, superheated steam, saturated steam, etc
  • A variety of optional structure form, pipe sections, plug-in, flange, etc.

Apure APT Air Vortex Flow Transmitter is a stress vortex street flow sensor based on karman vortex street principle. Widely applied to measure liquid, gas and steam (including compressed gas) the cumulative flow and transient flow, oil, chemical, metallurgical, and urban water supply, gas pipeline industry such as volume measurement of the ideal instrument.

Features:

  1. The accuracy is high, usually the measurement accuracy of liquid is ±1.0%, and the measurement accuracy of gas is ±1.5%. The measurement range is wide, up to 10:1.
  2. Allows a wide temperature range of the measuring medium, -25℃~+300℃.
  3. The pressure loss is small (about 1/4~1/2 of the orifice flowmeter), which is an energy-saving flow meter.
  4. The detection element is built in the vortex body and does not touch the fluid, ensuring high reliability, good signal-to-noise ratio, high sensitivity, and good zero point stability.
  5. The medium has strong adaptability and can measure liquid, gas, superheated steam, saturated steam, etc.
  6. Generally, compensation is not required when measuring liquid volume flow, and temperature and pressure compensation are required to measure steam mass flow and gas volume flow.
  7. No moving parts, wear-resistant, firm and simple structure, easy to maintain, and low cost of use.
  8. It is easy to install, and it can be installed horizontally, vertically and obliquely at different angles.
  9. A variety of structural forms are available, such as pipe segment type, plug-in type, flange type, flange-to-clamp type, etc.
  10. The caliber of the flow sensor is from DN15-DN300.
  11. Pulse signal output, or two-wire 4-20mA current signal output, with RS-485 interface, HART protocol, ModBus protocol optional communication function.
  12. The vortex flowmeter is widely used to measure the cumulative flow and instantaneous flow of liquid, gas and steam (including compressed gas). It is an ideal instrument for volume measurement in industries such as petroleum, chemical industry, metallurgy, urban water supply, and gas pipeline network.
Nominal path(mm)Flow range ( m³/h )
liquidgassteam
250.8~127.2~6012~120
402~3018~18030~300
503~4520~30050~500
656.5~8454~54084~840
8010~13070~700120~1200
10020~20012~1200200·2000
12532~320200~2000320~3200
15045~450240~2400440~4400
20090~900480~4800800~8000
25012~1200740~74001200~12000
30015~15001000~100001780~17800

Brand

ApureModel

AQTAccuracy

1.0%Nominal Path

DN15~DN300Material

Stainless SteelSignal output

4~20mAConnection

Flange connectionRepetitive

0.3%Power supply

+12VDC ~ 36VDC, 3.6V Lithium battery