AFT Split Type Electromagnetic Flow Meter
The Apure AFT is a split electromagnetic flow meter for conductive liquids. Its pipe-mounted sensor connects to a separately mounted converter, which can be positioned for access and suitable ambient conditions.
- Multi-functional Intelligent Converter
- Rapid response and high stability
- High-definition LCD Backlight Display
The sensor measures an induced voltage related to liquid velocity. The converter processes this signal and reports volumetric flow through the configured outputs. Choose the liner and electrodes for the liquid and select a location where the sensor remains full during operation. Confirm the permitted cable length and cable type for the sensor and converter supplied together. Check cable routing, shielding, potential equalization and the conditions at the converter mounting location against the installation instructions.
Installation and selection
Provide the liquid and its conductivity, the minimum, normal and maximum flow, process pressure and temperature, pipe size, and required output. Include the distance and route between the sensor and converter when requesting a configuration.
The published cable references are 30 m and 100 m. Confirm the permitted distance for the supplied sensor, converter, cable and liquid conductivity. The previous overview lists 10:1 and the specification table lists 150:1. Obtain the usable range and accuracy basis for the ordered assembly. Confirm the wetted materials and any required hazardous-area marking.
Listed liner and size combinations
Piped PTFE Lining: 10 15 20 25 32 40 50 65 80 100 125 150 200 250 300 350 400 450 500 600
Piped rubber lining: 40 50 65 80 100 125 150 200 250 300 350 400 500 600 800 1000 1200

| Brand | Apure |
|---|---|
| Model | AFT |
| Flow direction | positive and negative net flow |
| Measure extention ratio | 150:1 |
| Repeating erro | ±0.1% of the meterage |
| Accuracy grade | pipeline style: 0.5 1.0 |
| The temperature of themeasured medium | ordinary rubber underlay:-20~+60 High temperature rubber underlay:-20~+90 Polythene underlay: -30~+100 High temperature underlay:-30~+180 |
| Rating work pressure | Pipeline style : DN10-65:≤2.5MPA DN80-DN150:≤1.6MPA DN200- DN 1200:≤1.0MPA |
| Explosion-proof | md11BT4 |
| Power supply | 85~265V, 45~63HZ |
| Environmental temperature | -25~60℃ |