OIL-206A Online Oil In Water Sensor
The Apure OIL-206A is an optical sensor for monitoring oil-related changes in water. Confirm the supplied optical method, target hydrocarbons and calibration reference before interpreting its ppm indication.
- Easy calibration
- Low power consumption
- Measuring range is optional
- *The black plastic model has been discontinued, the default model is stainless steel
OIL-206A is an oil-in-water monitoring channel, not a redox-potential (ORP) electrode. Specify the oil or hydrocarbon fraction of interest, the water matrix and the required reference method.
Confirm the optical method and calibration basis
Fluorescence detects emitted light after excitation; absorbance measures attenuation of incident light. These are different methods. Confirm the actual optical method and spectral configuration in the supplied OIL-206A documentation. For a fluorescence measurement, response from aromatic constituents depends on the oil composition and calibration material; it is not a universal measurement of all dissolved, dispersed and total oil.
Validate in the intended water
- Identify the calibration oil or reference compound and the meaning of the ppm scale. Compare representative samples with the laboratory method that measures the intended hydrocarbon fraction.
- Check background fluorescence/colour, particles, bubbles, fouling and changes in the oil mixture. An optical correction or ambient-light filtering function does not remove every matrix effect.
- Use for process trends and contamination follow-up after site verification. Drinking-water, marine or wastewater applications need their own method and materials assessment; the reading alone does not certify safety or compliance.
Installation and service
- Select the listed range for the ordered version and confirm mounting, materials, supply and operating limits. The page notes that the black plastic model is discontinued and stainless steel is the default; confirm the current supplied housing.
- Keep the optical window representative of the water and accessible for inspection, cleaning and reference checks. Do not infer mains-AC supply from a description of light-source modulation.
- For the listed RS485 digital output, obtain the application protocol and register map. Verify units, settings and invalid-reading behaviour at the receiving device.
The original “Cable length: 20 meters underwater” entry is ambiguous: it does not independently establish both cable length and permitted immersion depth. Confirm these separately for the supplied housing and connector. Listed ppm ranges and error values are retained; their calibration material and accuracy basis still require confirmation.
| Brand | Apure |
|---|---|
| Model | OIL-206A |
| Measuring range | 0~40.00ppm, 0~70ppm, 0~150ppm |
| Resolution | 0.01ppm |
| Accuracy | ±3%, ±0.5℃ |
| Digital output | Isolated protection RS485 signal output |
| Cable length | 20 meters underwater |
| Temperature | -5~65℃ |