ACT Insertion Type Magnetic Flowmeter
Apure ACT Insertion Type Magnetic Flowmeter as the product of long-term experience in the field of flux instrument, has the functions of rapid response and output noise elimination Its design and quality control system have guaranteed the high accuracy and reliability of the product, and the application of lining makes the electromagnetic flowmeter applied more widely.
- Multi-functional Intelligent Converter
- Rapid response and high stability
- High-definition LCD Backlight Display
Apure ACT Digital Liquid Magnetic Flow Meter as the product of long-term experience in the field of flux instrument, has the functions of rapid response and output noise elimination Its design and quality control system have guaranteed the high accuracy and reliability of the product, and the application of lining makes the electromagnetic flowmeter applied more widely.
Flow direction | positive and negative net flow |
Measure extention ratio | 150:1 |
Repeating erro | ±0.1% of the meterage |
Accuracy grade | pipeline style: 0.5 1.0 |
The temperature of themeasured medium | ordinary rubber underlay:-20~+60 High temperature rubber underlay:-20~+90 Polythene underlay: -30~+100 High temperature underlay:-30~+180 |
Rating work pressure | Pipeline style : DN10-65:≤2.5MPA DN80-DN150:≤1.6MPA DN200- DN 1200:≤1.0MP |
Features
- There is no movable part in the pipes ,hence ,nothing resista the flow and to cause pressure loss or jamming.
- Measurement is free from series of influences e.g medium density,elasticity ,temperature or electrical conductivity.
- Corrosion resistance and wearability standard among other indexes are met via selecting different materials for lining and electrodes.
- The products are equipped with high resoluction backlighted LCD display, which is integrated with menus with both language of english and chinese, it is up to the users’ needs to modify the measuring range on site.
- The devices have also been integrated with series of communiction prorocals i.e.RS485. RS232 ,HART and MODBUS.
- With programmable low frequency rectangular wave excitation,flow stability is promoted on less power loss.
- Both power off protection and overrang alarming orients for measured calue,besides,it is also possible to change medium flow direction via programming the integrated sensor,which means installation of sensors are not limited to flow direction and messuring is operatable with both the flow directions.
- Thers instrument do not suit for measuring gas flw or nonconductive liquids.
Main technical parameter
Nominal path series DN(mm)
Piped PTFE Lining:10 15 20 25 32 40 50 65 80 100 125 150 200 250 300 350 400 450 500 600
Piped rubber lining:40 50 65 80 100 125 150 200 250 300 350 400 500 600 800 1000 1200
Brand | Apure |
---|---|
Model | ACT |
Measuring range | 0~14.00pH;0~135℃ |
Resolution | 0.01PH;0.1 ℃ |
Accuracy | 0.01PH+1Digit;0.1℃ +1Digit |
Electrode | 0.05cm-1 sanitary grade electrode,1/2″ thread |
Current output | Isolated protection 4-20mA signal output |
Cable length | 10m or others(5~30m) |
Working conditions | temperature : 0~50°c; Humidity : ≤85%RH |
Dimensions | 96× 96 × 130mm |
Cut off dimensions | 92X92mm |