A20 Digital Optical DO Meter

The Apure A20 Digital Optical DO Meter works with a compatible optical dissolved oxygen probe for online water monitoring. Select the matched sensor and controller configuration for the required DO range, installation and system interface.

  • Easy to operate
  • Widely used
  • Big screen

The A20 Digital Optical DO Meter is a controller for a compatible optical dissolved oxygen measurement system. Optical sensing uses an oxygen-sensitive luminescent layer rather than the pH glass-electrode measurement circuit. Confirm the supplied probe, controller version and interface together.

Select the complete DO system

  • Define the expected DO interval, reporting units, water type, temperature and installation. Confirm the actual sensor range and accuracy at that interval.
  • Check the matched probe, connector, cable, power supply and communication or analog output. A shared controller housing does not establish compatible sensor terminals.
  • Confirm where temperature, salinity and barometric-pressure inputs are entered and how the supplied system applies them. Do not assume that every correction is automatic.
  • Choose mounting and cleaning access that give the probe representative water and avoid trapped bubbles or a direct aerator plume.

Wiring and commissioning

Use the DO-specific connection drawing supplied with the ordered controller and probe. Check supply voltage, polarity, signal interface and output scaling before energizing. A glass/reference-electrode terminal diagram is not a wiring map for an optical DO probe. Request the matched drawing with the quotation.

Follow the supplied system’s startup, air/sample calibration and independent verification procedure. Record the sensor/controller identity, reference conditions, temperature, pressure/salinity settings and results. See the DO sensor selection and calibration guide.

Panel mounting reference

Confirm the supplied controller’s mounting dimensions and approved drawing before cutting a panel. Housing drawings do not establish the measurement range, sensor interface or electrical terminal assignments.

BrandApure
ModelA20 Digital Optical DO Meter
Measurement systemDissolved oxygen measurement with a compatible optical DO probe
Confirm the supplied configurationDO range and units, accuracy basis, temperature input, compensation functions, matched sensor and calibration procedure
Electrical and mounting detailsConfirm power, interface, outputs/relays, terminal drawing, cable, enclosure and panel dimensions for the ordered DO version.